Digital PID Temperature Controller REX-C900 Thermocouple Input Relay/SSR Output

@ MODERN HALLROAD

Digital PID Temperature Controller REX-C900 Thermocouple Input Relay/SSR Output in pakistan BR1425
1. Input
Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals.
2. Accuracy
Measure accuracy ±0.5%FS
Compensation error of cold termina ±2°C(amend within 0~50°C by soft)
<![if !supportLineBreakNewLine]>
<![endif]>
Resolution 14bit
Sampling period 0.5Sec.
3. Display
PV,SV -1999 ~ +1999
Output( OUT1,OUT2) Alarm(Alarm1,Alarm2) Auto setting(AT) Display LED
4.Control way
Control way 1 Auto Setting Control
Control way 2 PID Control(including ON/OFF, position PID and continuous PID)
5. Controlling output
Currency output DC 0~10Ma,4~20mA(RL less than 500Ω)
Voltage output DC 0-5V,1-5V(RL more than 10K)
Relay output contact capacity 250VA (resistance load)
Voltage Impulse output 0~12V, (suitable for the solid relay SSR)
Silicon Controlled Rectifier(SCR) output zero-cross triggering or phase-shift triggering(resistive load)
Capacity of the output contact 250V AC 3A (resistant load)
Alarm output 2 groups output at most,12 modes
6. Setting range
Setting value (SV) Measured Present Value (PV)
Proportional band (P) 0 ~ whole measured range (when set 0, it’s ON/OFF control
Integral time 0~3600 Sec (when the time is 0, the function of integral time closed)
Derivative time 0~ 3600 Sec (when the time is 0, the function of differential time closed)
Proportional term 1~100 Sec
On-off control output hysteretic loop width 1~100℃ (or other pv units)

 2,660.00

Out of stock

Category:

Digital PID Temperature Controller REX-C900 Thermocouple Input Relay/SSR Output in pakistan BR1425

1. Input
Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals.
2. Accuracy
Measure accuracy ±0.5%FS
Compensation error of cold termina ±2°C(amend within 0~50°C by soft)
<![if !supportLineBreakNewLine]>
<![endif]>
Resolution 14bit
Sampling period 0.5Sec.
3. Display
PV,SV -1999 ~ +1999
Output( OUT1,OUT2) Alarm(Alarm1,Alarm2) Auto setting(AT) Display LED
4.Control way
Control way 1 Auto Setting Control
Control way 2 PID Control(including ON/OFF, position PID and continuous PID)
5. Controlling output
Currency output DC 0~10Ma,4~20mA(RL less than 500Ω)
Voltage output DC 0-5V,1-5V(RL more than 10K)
Relay output contact capacity 250VA (resistance load)
Voltage Impulse output 0~12V, (suitable for the solid relay SSR)
Silicon Controlled Rectifier(SCR) output zero-cross triggering or phase-shift triggering(resistive load)
Capacity of the output contact 250V AC 3A (resistant load)
Alarm output 2 groups output at most,12 modes
6. Setting range
Setting value (SV) Measured Present Value (PV)
Proportional band (P) 0 ~ whole measured range (when set 0, it’s ON/OFF control
Integral time 0~3600 Sec (when the time is 0, the function of integral time closed)
Derivative time 0~ 3600 Sec (when the time is 0, the function of differential time closed)
Proportional term 1~100 Sec
On-off control output hysteretic loop width 1~100℃ (or other pv units)

Vendor Information

  • Store Name: MODERN HALLROAD
  • Vendor: MODERN HALLROAD
  • Address:
  • 5.00 5.00 rating from 1 review
Digital PID Temperature Controller REX-C900 Thermocouple Input Relay/SSR Output
Digital PID Temperature Controller REX-C900 Thermocouple Input Relay/SSR Output

 2,660.00

Majju PK
Logo
Reset Password
Shopping cart